MK S2/4-1500 , MK S4-1500 Automatic Test System |
Current |
5mA to 1000mA Programmable 1mA |
Voltage |
1V to 30V Programmable to 1V |
High
Voltage DC |
Voltage |
25V to 1500V Programmable 5V |
Current |
0.1uA to 4000uA |
High
Voltage AC (when fitted) |
Voltage |
25V to 1000V RMS @ 50 Hz Programmable to
5V |
Current |
1uA to 5000uA |
Typical
Test Performance |
Continuity |
Switching speed > 50000 points per second
0.05s per established connection
0.05s shorts test per point |
Insulation and Hi-pot |
Programmable Ramp, Pre Dwell and Dwell times.
Minimum 0.1s per point |
Measurements |
Continuity |
0.002次 to 100K次 (4-wire mode)
0.1次 to 100K次(2 wire mode)
Accuracy 0.5% +/- 0.002次@ 1000mA (4-wire mode)
Accuracy 0.5% +/- 0.1次 @ 1000mA (2-wire mode)
Resolution 0.001次 (4-wire mode)
Resolution 0.1次 (2-wire mode) |
DC Insulation |
5K次 to 1000M次 Accuracy 5% |
AC Hi-pot |
1uA to 5000uA Accuracy 5% |
Interface |
32 off 4 wire (Kelvin) Test points
per board
64 off 2 wire Test points per board
Maximum 512 test points per sub-rack, maximum
512 sub-racks, 262144 points
Connection via high specification 37 way "D"
type sockets
Connection on pins 1 to 32,33 to 37 not used,
interlock on front panel |
Options |
Extended continuity range up to
1M次
Increased continuity test current up to 10A
Custom voltages up to 100KV
External Instruments and customised electrical
tests
Communication with other devices
Customised import facility for programme creation |